Guangdong Jingyuan Technology Co., Ltd.Guangdong Jingyuan Technology Co., Ltd.GUANGDONG JINGYUAN
Home/Test Data/Flame-retardant Nylon: 5%, 10% and 15%
TEST / JINGYUAN MATERIALS

Flame-retardant Nylon: 5%, 10% and 15%

The source records the stated formulation and comparative results. Values apply only to the listed material and test conditions.

Flame-retardant Nylon: 5%, 10% and 15%
MICRO / APPLICATIONFlame-retardant Nylon: 5%, 10% and 15%
QUICK CATEGORY SWITCH

Switch related sections without returning home

Test evidence, technical insight and files are organised separately for review and download.

STRUCTURED DATA

Parameters and test conditions

Structured backend fields are presented directly for selection and comparison.

Best in group
10%
Test date
2025-07-16
Notched impact
8.1→11.3 kJ/m²
Tensile strength
104→125 MPa
Baseline
常规配方
Flexural strength
139→173 MPa
Test standard
ISO 527 / ISO 178 / ISO 180

EVIDENCE NOTEData applies to the stated material, formulation and test conditions and is for selection and pilot-test reference only.

The source records the stated formulation and comparative results. Values apply only to the listed material and test conditions.

Use of data

Use this record to select dosage ranges and validation targets. It is not a performance guarantee for other resins, formulations or processes.

What the record contains

The page retains material system, dosage, baseline, principal values, standard and date. Results indicate direction within the stated formulation and must not be transferred to another grade or specimen preparation without verification.

How to read the data

  1. Check matrix, filler combination and surface treatment.
  2. Compare blank and experimental groups under the same standard.
  3. Review strength, toughness, flow and cost together.
  4. Before production, retest batch stability, process window and long-term performance.

Customer replication

Recreate the baseline with actual raw materials and equipment and use at least two dosage levels. When replacing glass fibre or conventional filler, also record thickness, weight, shrinkage, surface quality and cycle time.

DATA LEDGER

Parameters and test conditions

Best in group
10%
Test date
2025-07-16
Notched impact
8.1→11.3 kJ/m²
Tensile strength
104→125 MPa
Baseline
常规配方
Flexural strength
139→173 MPa
Test standard
ISO 527 / ISO 178 / ISO 180
APPLICATION DESK

Submit a Request

Crystal-form selection, surface treatment, formulation matching, pilot tests and scale-up support.